Burn-In Test log info

Log ID
 
Measure date
 
Test ID
 
Position
 
Options
 
165
 
2025-08-08 17:11:45
 
2610
 
8
 
 

Test log info

Log ID
 
Log date
 
Part name
 
Test type
 
Station
 
Operator
 
In Spec
 
2610
 
2025-08-11 12:20:11
 
Burn-In
 
Feng
 
 

Stored files

File ID
 
Path
 
Options
 
 
 
 
 

Comments

HV current jumped to 20µA and went back to normal range during the IV measurement at 20ºC at the end of the last cycle, which influenced the readout test. Module seems OK.

Measurements

to zoom: shift+drag/scroll
{ "bias": [ 600, 600, 600, 600, 600, 600 ], "opens": [ 0, 0, 0, 0, 0, 0 ], "noisys": [ 0, 0, 0, 0, 0, 839 ], "in_specs": [ 1, 1, 1, 1, 1, 0 ], "stop_times": [ "2025-08-08T15:20:13+00:00Z", "2025-08-08T17:30:54+00:00Z", "2025-08-08T22:54:11+00:00Z", "2025-08-09T04:14:44+00:00Z", "2025-08-09T10:31:55+00:00Z", "2025-08-09T10:48:21+00:00Z" ], "start_times": [ "2025-08-08T15:11:45+00:00Z", "2025-08-08T17:22:14+00:00Z", "2025-08-08T22:42:09+00:00Z", "2025-08-09T04:07:44+00:00Z", "2025-08-09T09:30:50+00:00Z", "2025-08-09T10:42:06+00:00Z" ], "temperatures": [ "20", "-33", "-33", "-33", "-33", "20" ] }