Burn-In Test log info

Log ID
 
Measure date
 
Test ID
 
Position
 
Options
 
35
 
2025-03-31 17:49:39
 
877
 
2
 
 

Test log info

Log ID
 
Log date
 
Part name
 
Test type
 
Station
 
Operator
 
In Spec
 
877
 
2025-04-01 16:47:10
 
Burn-In
 
 
 

Stored files

File ID
 
Path
 
Options
 
 
 
 

Comments

full test during 4 thermal cycles. Module 10008 was biased in 500V

Measurements

to zoom: shift+drag/scroll
{ "start_times": [ "2025-03-31T15:49:39+00:00Z", "2025-03-31T16:34:38+00:00Z", "2025-03-31T19:28:19+00:00Z", "2025-03-31T21:37:34+00:00Z", "2025-04-01T00:35:28+00:00Z", "2025-04-01T02:44:48+00:00Z", "2025-04-01T05:41:20+00:00Z", "2025-04-01T07:51:34+00:00Z", "2025-04-01T10:45:54+00:00Z", "2025-04-01T12:55:11+00:00Z" ], "stop_times": [ "2025-03-31T15:57:53+00:00Z", "2025-03-31T18:02:44+00:00Z", "2025-03-31T20:57:46+00:00Z", "2025-03-31T23:07:07+00:00Z", "2025-04-01T02:04:47+00:00Z", "2025-04-01T04:14:44+00:00Z", "2025-04-01T07:11:18+00:00Z", "2025-04-01T09:21:35+00:00Z", "2025-04-01T12:15:11+00:00Z", "2025-04-01T14:26:46+00:00Z" ], "temperatures": [ "20", "20", "-34", "20", "-34", "20", "-34", "20", "-34", "20" ], "bias": [ 600, 600, 600, 600, 600, 600, 600, 600, 600, 600 ], "opens": [ 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 ], "noisys": [ 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 ], "in_specs": [ 1, 1, 1, 1, 1, 1, 1, 1, 1, 1 ] }